Statistical and Metrological Framework for Evaluation of micro-CT3D Data with Application to Dental Implant Components

Authors

  • Miroslav Hain Institute of Measurement Science, Slovak Academy of Sciences, Bratislava, Slovakia https://orcid.org/0000-0002-3075-9638
  • Alexander Šatka Institute of Measurement Science, Slovak Academy of Sciences, Bratislava, Slovakia
  • Tomáš Czán Institute of Measurement Science, Slovak Academy of Sciences, Bratislava, Slovakia
  • Andrej Czán Faculty of Mechanical Engineering, University of Žilina, Žilina, Slovakia
  • Mário Drbúl Faculty of Mechanical Engineering, University of Žilina, Žilina, Slovakia
  • Jaromír Markovič Faculty of Mechanical Engineering, University of Žilina, Žilina, Slovakia
  • Viktor Witkovský Institute of Measurement Science, Slovak Academy of Sciences, Bratislava, Slovakia https://orcid.org/0000-0001-5166-4745

DOI:

https://doi.org/10.2478/msr-2026-0033

Keywords:

micro-computed tomography, dental implant, dimensional metrology, empirical distribution, Kolmogorov–Smirnov statistic, surface deviation

Abstract

Dimensional comparison of micro-computed tomography (micro-CT) reconstructions with CAD geometry requires a precise defnition of the evaluated surface points. We apply a statistical and metrological framework to signed CAD–CT deviations at the vertices of three geometrically different titanium dental implant components, D1–D3, representing complex surface geometry, substantial µCTto-CAD deviations, and ambiguous initial alignment. Complete exports contain 75 812, 46 954, and 16 416 measured-surface vertices. The corresponding RMS deviations are 49.14 µm, 207.72 µm, and 77.07 µm. Empirical cumulative distribution functions, histograms normalized to unit area, and descriptive summaries compare the observed meshes; two-sample Kolmogorov–Smirnov (KS) distances quantify differences between their vertex distributions. D2 has the largest absolute-deviation upper tail. A detailed axial analysis of D1 localizes all 267 vertices with absolute deviation above 200 µm in one of 12 intervals. Separate area-sampled and radial D1 exports provide sensitivity checks for alternative surface and correspondence defnitions. Because vertices are spatially dependent and mesh density determines their weighting, conventional KS p-values are only nominal reference calculations. A prospective observation model distinguishes physical deviation from measurement and alignment effects. The workfow provides a reproducible basis for statistical evaluation and measurement-uncertainty assessment of individual components.